Troubleshooting – Desa LCF24 User Manual

Page 14

Advertising
background image

www.desatech.com

115043-01C

14

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Gas supply turned off or equip-

ment shutoff valve closed

2. Control knob not in PILOT

position

3. Control knob not pressed in

while in PILOT position

4. Air in gas lines when in-

stalled

5. Pilot adjustment screw

closed

6. Pilot is clogged

7. Low gas pressure

1. Control knob not fully

pressed in

2. Control knob not pressed in

long enough

3. Equipment shutoff valve not

fully open

4. Pilot flame not touching

thermocouple, which allows

thermocouple to cool, caus-

ing pilot flame to go out. This

problem could be caused by

one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

pilot

5. Thermocouple connection

loose at control valve

6. Thermocouple damaged

7. Control valve damaged

1. Burner orifice clogged

2. Inlet gas pressure is too low

3. Thermocouple leads dis-

connected or improperly

connected

1. Pilot flame needs adjusting

2. Wrong pilot orifice

OBSERVED PROBLEM

When ignitor button is pressed,

there is spark at pilot but no igni-

tion (GA9050A Only)

Pilot lights but flame goes out

when control knob is released

(GA9050A Only)

Burner does not light after pilot

is lit (GA9050A Only)

Delayed ignition burner

(GA9050A Only)

REMEDY

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while in

PILOT position

4. Continue holding down control

knob. Repeat igniting opera-

tion until air is removed

5. Adjust pilot flame for approxi-

mately 2" blue flame

6. Clean pilot (see Cleaning and

Maintenance, page 12) or

replace pilot assembly

7. Replace gas control

1. Press in control knob fully

2. After pilot lights, keep control

knob pressed in 30 seconds

3. Fully open equipment shutoff

valve

4. A) Contact local natural gas

company

B) Clean pilot (see Cleaning

and Maintenance, page 12) or

replace pilot assembly

5. Hand tighten until snug, then

tighten 1/4 turn more

6. Replace thermocouple

7. Replace control valve

1. Clean burner orifice

2. Contact local natural gas

company

3. Reconnect leads

1. Adjust pilot flame for approxi-

mately 2" blue flame

2. Replace pilot orifice set