The fireplace must include a working flue and

venting system with the minimum openings shown

in the Figure 2.

INSTALLATION

Continued

Figure 2 - Technical Information Charts

Model

Burner

Descrip-

tion

BTU Input

(Natural

Gas)

Min.

Vent

Opening

LCF18

18" Dual

55,000

8"

LCF24

24" Dual

60,000

8"

Minimum Fireplace Dimensions

Model

Front

Width

Back

Width*

Depth

Height

LCF18

28"

18"

14"

16"

LCF24 29.75"

17"

15.5"

18"

* At depth Indicated

Fuel Inlet Pressure

Specifications (W.C.)

Min.

Max.

N.G.

5.5"

10.5"

Burner Orifice Sizing

Log Size

Natural Gas

In.

Num.

18"

.120

31

24"

.129

30

CHECK GAS TYPE

Use only natural gas. If your gas supply is not

natural gas, you must install ON/OFF Safety

Valve/Pilot Kit (see Accessories, page 18). Call

dealer where you bought log set.
If the fireplace does not have a gas supply shutoff

valve, one must be installed.

VENTING SPECIFICATIONS FOR
INSTALLATION

The fireplace chimney flue and vent must be draft-

ing properly. To check the vent for proper drafting:

Light a tightly rolled newspaper on one end and

place it at the inside front edge of the fireplace.

Observe the smoke and be sure the vent is properly

drawing it up the chimney. If the smoke spills out

into the room, extinguish the flame and remove any

obstruction until proper venting is achieved.
The chimney flue must remain open a minimum

of 3" at all times during the operation of this

log set.

INSTALLING DAMPER CLAMP

Secure the damper stop clamp provided to the

leading edge of the damper as shown in Figure 3.

If for any reason this clamp doesn't work on your

fireplace, another suitable clamp or permanent

stop must be installed, or the damper blade must

be cut or removed.

CONNECTING TO GAS SUPPLY

WARNING: A qualified ser-

vice person must connect log

set to gas supply. Follow all

local codes.

Installation Items Needed
Before installing log set, make sure you have the

items listed below.
• piping (check local codes)
• sealant (resistant to Propane/LP gas)
• equipment shutoff valve
• test gauge connection
• adjustable (crescent) wrench or pliers
• sediment trap
• tee joint
• pipe wrench

Figure 3 - Attaching Damper Clamp

Damper
Clamp

Damper
Clamp

Damper

Manufactured