Installation – Desa LCF24 User Manual

Page 8

Advertising
background image

www.desatech.com

115043-01C

8

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 5).
2. Pressurize supply piping system by either us-

ing compressed air or opening main gas valve

located on or near gas meter.

3. Check all joints from gas meter to equipment

shutoff valve (see Figure 5). Apply noncorro-

sive leak detection fluid to gas joints. Bubbles

forming show a leak.

4. Correct all leaks at once.

INSTALLATION

Continued

Figure 5 - Checking Gas Joints

HEARTH KIT ASSEMBLY AND
INSTALLATION

1. Determine which side the gas line will be coming

into the fireplace.

2. Using a hammer and screw driver, remove

knockout plug from the side of the pan that

corresponds to the gas line (see Figure 6).

3. Unscrew burner inlet fitting from burner

manifold.

4. Place burner manifold in pan with threaded

opening facing open knockout plug.

5. Using thread sealant (resistant to the action

of propane/LP gas) on larger end of fitting,

screw the burner inlet fitting through hole and

into burner manifold (see Figure 6). Tighten

using a wrench.

6. Using burner clamp, screw, and nut provided,

assemble clamp to pan (“U” style and triple

burners only). This will hold the burner mani-

fold in place.

7. If using optional GA9050A kit, go to Optional

GA9050A On/Off Safety Valve/Pilot Kit section

for installation instructions. If using optional

GA9150A kit, follow instructions included

with kit for installation and operation.

Figure 7 - Connecting Gas to Appliance

Adapter
Fitting

Gas
Connector
Tube

Burner Pan Assembly
(Facing Front of
Fireplace)

Figure 6 - Installing Burner

Burner Inlet
Fitting

Screw

Nut

Burner
Clamp

Burner Pan
(Front)

Burner Manifold

Knockout
Plugs

Installation and Gas Connection
1. Place the burner pan assembly in the center

of the fireplace floor. Make sure the front of

pan faces forward.

2. Thread the gas supply fitting to the fireplace

gas supply pipe. Use thread sealant.

3. Install adapter fitting onto the burner inlet

fitting using thread sealant on male threads

of burner inlet fitting (see Figure 7). Adjust

to most convenient position.

4. Install the gas connector tube to the gas sup-

ply fitting. Carefully shape tube to attach to

adapter fitting. Be careful not to cause kinks

in tube.

Gas Meter

Equipment Shutoff Valve

Advertising
This manual is related to the following products: