Specifications, Replacement parts, Service hints – Design Dynamics DVF-36S-N User Manual

Page 24: Technical service, Cleaning and maintenance

Advertising
background image

www.desatech.com

120441-01A

24

WARNING: Do not operate fire-

place with glass door unlatched,

removed, cracked or broken.

PILOT AND BURNERS

• Remove material before cleaning burners

and replace when cleaning is complete.

• Burner and controls should be cleaned

with compressed air to remove dust, dirt
or lint.

• Use a vacuum cleaner or small, soft bristled

brush to remove excess dust, dirt or lint.

LOGS

• Use a vacuum cleaner to remove any

carbon buildup on logs.

• Replace material periodically as needed.

See Replacement Parts.

VENTING SYSTEM

Conduct annual inspection of the venting
system following these guidelines:
1. Check areas of venting system that are

exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced im-
mediately by a qualified service person.

2. Remove the vent cap and shine a flash-

light into the vent. Remove any foreign
material.

3. Check for evidence of excessive con-

densation. Continuous condensation can
cause corrosion of caps, pipes and fittings
and can be caused by having excessive
lateral runs, too many elbows or exterior
portions of the system being exposed to
cold weather.

4. Inspect joints to verify that no pipe section

or fitting has been disturbed and loos-
ened. Check mechanical supports such
as wall straps for rigidity.

technicAL Service

You may have further questions about instal-
lation, operation or troubleshooting. If so,
contact DESA’s Customer Service Depart-
ment at 1-866-672-6040. When calling, please
have your model and serial numbers of your
heater ready.
You can also visit DESA’s technical service
web site at www.desatech.com.

cLeAninG AnD

MAintenAnce

Continued

SPeciFicAtiOnS

DVF-36S-N, DVF-36H-N, DVF-36SC-N,
DVF-36HC-N
• Rating: 66,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c.
• Minimum Inlet Supply Pressure: 7.0" w.c.
DVF-36S-P, DVF-36H_P, DVF-36SC-P,
DVF-36SH-P
• Rating: 62,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Electronic
• Manifold Pressure: 10.0" w.c.
• Minimum Inlet Supply Pressure: 11.0" w.c.

rePLAceMent PArtS

Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.

pARTS UNDER WARRANTY

Contact authorized retailers of this product.
If they can not supply original replacement
part(s), call DESA’s Customer Service Depart-
ment at 1-866-672-6040.
When calling DESA, have ready
• your name
• your address
• model and serial numbers of your fire-

place

• how fireplace was malfunctioning
• type of gas used (propane/LP or natural

gas)

• purchase date
Usually, we will ask you to return the part to
the factory.

pARTS NOT UNDER WARRANTY

Contact authorized retailers of this product.
If they can not supply original replacement
part(s), call DESA at 1-866-672-6040 for
referral information.
When calling DESA, have ready
• model number of your fireplace
• the replacement part number

Service hintS

When Gas pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply might be low (pro-

pane/LP units only)

You may feel your gas pressure is too low. If
so, contact your local gas supplier.

Advertising