ventinG inStALLAtiOn

NOTICE: Read these instruc-

tions completely before at-

tempting installation.

These models are tested and approved for
use with DESA (direct vent) pipe components
and terminations.
The venting system must terminate on the
outside of the structure and can not be at-
tached to a chimney or flue system serving a
separate solid fuel or gas burning appliance.
A direct vent appliance must have its own
venting system. DO NOT common vent this
appliance.
These models are approved to be vented
either horizontally through an outside wall or
vertically through a roof or chase enclosure
using the following guidelines:
• When venting system terminates horizon-

tally on an outside wall, you may install
a standoff if the termination cap is to be
installed directly on a combustible finish
such as vinyl, wood, stucco, etc.

• Never run the vent downward as this may

cause excessive temperatures which could
cause a fire.

• Vent pipe air space clearances to com-

bustibles are 1" on all sides except on the
horizontal sections, which requires 2" clear-
ance from the top of the pipe. Where the
termination cap penetrates a combustible
wall, 1" air space clearance is required.

• Have fireplace and selected vent compo-

nents on hand to help determine the exact
measurements when elbowing or offsetting.
Always use wall firestops when penetrating
walls and firestops when penetrating ceil-
ings or attic spaces.

• For installation of fireplace at elevations of

4000 feet or greater, pay special attention
to venting requirement recommendations.

WARNING: Read all instruc-

tions completely and thoroughly

before attempting installation.

Failure to do so could result in

serious injury, property damage

or loss of life.

NOTICE: Failure to follow these in-

structions will void the warranty.

NOTICE: Do not seal termination

cap to vent pipe. Cap must be

removable for vent inspection

and maintenance.

INSTALLATION pRECAUTIONS

• Wear gloves and safety glasses for

protection

• Use extreme caution when using ladders

or when on roof tops

• Be aware of electrical wiring locations in

walls and ceilings

The following actions will void the warranty
on your venting system:
• Installation of any damaged venting

component

• Unauthorized modification of the venting sys-

tem (Do not cut or alter vent components)

• Installation of any component part not

manufactured or approved by DESA

• Installation other than as instructed by

these instructions

WARNING: This gas fireplace

and vent assembly must be

vented directly to the outside.

The venting system must NEVER

be attached to a chimney serv-

ing a separate solid fuel burning

appliance. Each direct vent gas

appliance must use a separate

vent system. Do not use com-

mon vent systems.

WARNING: Vent pipe air

space clearances to combus-

tibles are 1" on all sides except

on the horizontal sections,

which require 2" clearances

from the top of the pipe. Where

the termination cap penetrates

a combustible wall, 1" air space

clearance is required.