Cv 95 reverse trim – SoundTraxx DSD-150/DSX Technical Reference User Manual

Page 46

Advertising
background image

Address Mode

Direct Mode

Register Mode

Ops Mode Short Form

Paged Mode

Ops Mode Long Form

46

Digital Sound Decoder Technical Reference

CV 95
REVERSE TRIM

Description
Contains a value, n, between 0 and 255 that specifies a scaling factor interpreted as
N/128 by which the reverse drive voltage is multiplied.

bit 7

bit 0

D7

D6

D5

D4

D3

D2

D1

D0

D0-D7:

Reverse Trim Scalar

The reverse trim scalar allows the decoder’s overall throttle response in the reverse direction to
be adjusted up or down for the purpose of matching one locomotive’s speed curve to another.

A trim value of 128 (0x80) yields a scaling factor of 1.0 which will have no net effect on the speed
response.

Trim values between 129 and 255 (0x81-0xFF) have the effect of increasing the motor voltage by
a factor ranging between 1.01 to 1.99.

Trim values between 1 and 127 (0x01-0x7F) will decrease the motor voltage by a factor between
0.008 and 0.99.

A trim value of 0 disables the trim scalar computation.

This CV is used only when speed tables are enabled (CV 29, Bit 4 = 1). Otherwise, this CV will
have no effect.

Default Value:

128 (0x80)

Related CVs:

See also Forward Trim, CV 29.