Sundance SMT350 User Manual
Page 20

Version 1.9
Page 20 of 45
SMT350 User Manual
21
D-12V0
Digital –12.0 Volts – not used on the SMT350
22 DGND Digital
Ground
23
D-12V0
Digital –12.0 Volts – not used on the SM350
24 DGND Digital
Ground
25 DGND Digital
Ground
26
EMU0
Emulation Control 0 – not used on SMT350
27
EMU1
Emulation Control 1 – not used on SMT350
28
TMS
JTAG Mode Control – not used on SMT350
29
nTRST
JTAG Reset – not used on SMT350
30
TCK
JTAG Test Clock – not used on SMT350
31
TDI
JTAG Test Input – not used on SMT350
32
TDO
JTAG Test Output – not used on SMT350
33 DGND Digital
Ground
Figure 10 – Mezzanine Module Interface Power Connector and Pinout.
The following few pages describes the signals on the data connector between the
main module and the daughter card. Bank A on the connector is used for the ADC
Channels A and B. Bank C is used for the DAC channels A and B. Bank B is used for
system clock and trigger signals, ADC/DAC/Clock control signal.