Sundance SMT350 User Manual
Page 30

Version 1.9
Page 30 of 45
SMT350 User Manual
1
0
1
All outputs are zeroes
2
1
0
All outputs are ones
3
1
1
Continuous stream of ‘10’
ADCB Register 2 – 0x7.
For more details, refer to ADS5500 datasheet.
ADCB Register 2 – 0x7
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
Reserved PDN
Reserved
Default
‘000’ ‘0’
‘000’
0
Reserved
Default
‘00000000’
ADCB Register 2 – 0x7
Setting
PDN
Description
0
0
Normal Mode of Operation
1
1
Device in Power Down Mode
DAC Register 0 – 0x8.
For more details, refer to DAC5686 datasheet.
DAC Register 0 – 0x8
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
atest Version
Default
‘000000’ ‘000’
1
Freq_int[7:0]
Default
‘00000000’
DAC Register 1 – 0x9.
For more details, refer to DAC5686 datasheet.
DAC Register 1 – 0x9
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Freq_int[15:8]
Default
‘00000000’
1
Freq_int[23:16]
Default
‘00000000’