Appendix e: troubleshooting, Appendix e, Troubleshooting – Q-See QSC26404 User Manual

Page 86

Advertising
background image

QSC26404 User’s Manual

86

Appendix E: Troubleshooting

Failure

Possible reasons

After plugging in power, turning on the power switch,

“POWER” light in front Panel does not turn on, and fan

does not work.

1) Power cable is damaged.

2) Power supply is damaged.

After plugging in power, turning on the power switch,

“POWER” light in front panel turns to green while fan does

not work.

1) Front panel cable is

damaged.

2) Fan is broken.

After plugging in power, turning on switch, “POWER”

light turns to green, the indicator lights in the panel turn on

at the same time, but fan does not work.

The ATX plug in main board is

not attached well.

DVR continuously reboots after start up, and makes a

sound like “di” every 10 seconds.

1) Upgraded

using

wrong

firmware

2) Compression board has

problems.

3) Main board has problems.

There are no images in the monitor connected with VOUT

after DVR is started.

1) The cable connected with the

monitor is damaged.

2) Real board of DVR has

problems.

3) Main board of DVR has

problems.

Cannot find the hard disk in reboot process.

1) Hard disk cable is damaged.

2) The power cable of hard disk

is not connected.

3) Hard disk is damaged.

DVR can not control PTZ through RS-485 port.

1) RS-485 cable is not

connected correctly or

damaged.

2) PTZ parameters error.

3) RS-485 port of DVR is

damaged.

Client software can not view DVR live image.

1) Network error.

2) Wrong DVR setup (wrong

IP, port number, username or

password, etc).

3) Old player SDK (playm4.dll)

Notes:

1)

Place the DVR in well ventilated area so that it operates within the recommended range of

temperature and humidity as in specifications.

2)

If the circuit board gets wet, dust on circuit board can cause a short circuit. The circuit board,

plug and socket, housing fan and housing should be cleaned by brushing.