Installation, Continued – Desa CGCFTP User Manual

Page 15

Advertising
background image

www.desatech.com

111044-01F

15

9. Install the switch plate on the valve cover

shield with 2 #10 screws provided (see Figure

19). Reinstall the valve cover shield. Route

power cord out of the cabinet by inserting it

through the bushing on the outer casing (see

Figure 18, page 14). Plug fan kit into 120-Volt

grounded power supply and test operation.

Note:

When switch is in the AUTO position,

the fan will start after the heater has run for

a few moments. The fan will continue to run

for several moments after the heater has been

turned off. When switch is in the ON position,

the fan will run until turned to OFF. Reinstall

upper louver assembly and hood if previously

removed, (see Figure 16, page 13). Close

lower louver door.

INSTALLATION

Continued

Figure 19 - Installing Switch Plate to

Valve Cover Shield

Switch
Plate

Screw

Valve Cover
Shield

For Built-In Installation

WARNING: A licensed elec-

trician must connect the wiring

harness to electrical supply

following all local codes. Electri-

cian must provide a clamp on the

box cover to secure the wiring.

Wiring should be routed through

the bushing in the hole on the

outer casing of heater.

Follow instructions in Removing Valve Cover

Shield, page 14, then
1. Install a snap bushing found in hardware kit

into one of the holes found on rear of valve

cover shield. The other hole is for a strain

relief clamp (not supplied) to secure incoming

electrical supply.

2. Follow steps 2 through 6 in Installing Blower

Assembly, page 14. Also

remove black wire

from middle switch terminal 2.

3. Remove black plastic strain relief and power

cord from switch plate. The power cord supplied

will not be used in built-in installations. Pop in

the plastic snap bushing found in hardware kit

into the hole left by supply cord/strain relief.

4. A licensed electrician must follow the wiring

diagram to connect incoming electrical supply

to fan kit wiring harness (see Figure 20).

5. Plug power cord to the outlet receptacle (not

provided) as shown in Figure 21. Wind the

extra cable in power cord and tie it up with

the plastic wire strap (see Figure 21). Set the

cable bundle between the burner bracket and

outer casing, away from the burner.

6. Reinstall valve cover shield.
7. Test to make sure the blower is working

properly.

8. Reinstall upper louver assembly and hood if

previously removed, (see Figure 16, page 13).

Close lower louver door.

Figure 20 - Wiring Diagram For Blower

Accessory Built-In Installation

Red

Red

Fan Switch

(Auto/Off/On)

Blue

Blue

Thermostat

Switch

(N.O.)

Green

White

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

3

Auto

Blower Bracket
Assembly

Screw

Wire
Harness

Power
Cord

Valve Cover
Shield

Box
Cover

Wire
Harness

Switch
Plate

Switch

Clamp
Connector
(not included)

Outlet
Receptacle

Blue

Red

Plastic Wire
Strap

Figure 21 - Installing Blower Bracket

Assembly