OPERATING FIREPLACE

Continued

LIGHTING

INSTRUCTIONS

WARNING: You must operate

this fireplace with the fireplace

screen in place. Make sure fire-

place screen is installed before

running fireplace.

NOTICE: During initial operation

of new fireplace, burning logs

will give off a paper-burning

smell. Orange flame will also be

present. Open window to vent

smell. Operate fireplace on HI

position to burn off odor. This

will only last a few hours.

1. STOP! Read the safety information on

page 19.

2. Make sure equipment shutoff valve is fully

open.

3. Turn control knob clockwise

to the

OFF position.

4. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information above. If you donʼt smell

gas, go to the next step.

5. Turn control knob counterclockwise

to the PILOT position. Press

in control knob for five (5) seconds (see

Figure 30).

Note:

You may be running this fireplace for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

• If control knob does not pop up when

released, contact a qualified service person

or gas supplier for repairs.

6. With control knob pressed in, push down

and release ignitor button. This will light

pilot. The pilot is attached to the front of

burner. If needed, keep pressing ignitor

button until pilot lights.

Note:

If pilot does not stay lit, refer to

Troubleshooting, page 23. Also contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure, page 21.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

Note:

If pilot goes out, repeat steps 3

through 7. This fireplace has a safety in-

terlock system. Wait one (1) minute before

lighting pilot again.

8. Turn control knob counterclockwise

to desired heating level. The main

burner should light. Set control knob to any

heat level between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Ignitor
Button

Figure 30 - Control Knob In The OFF

Position

Control
Knob

Thermocouple

Pilot Burner

Figure 31 - Pilot

Ignitor
Electrode

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1. Turn control knob clockwise

to the

OFF position.

2. Turn off all electric power to the appliance

if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

Advertising