Troubleshooting – Desa CGCFTP User Manual

Page 25

Advertising
background image

www.desatech.com

111044-01F

25

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

Yellow flame during burner

combustion

Slight smoke or odor during initial

operation

Fireplace produces a whistling

noise when burner is lit

White powder residue forming

within burner box or on adjacent

walls or furniture

POSSIBLE CAUSE

1. Not enough air

2. Gas regulator defective

1. Residues from manufacturing

processes

1. Turning control knob to HI

position when burner is cold

2. Air in gas line

3. Air passageways on fireplace

blocked

4. Dirty or partially clogged

burner orifice

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. may turn into

white powder residue

REMEDY

1. Check burner for dirt and

debris. If found, clean burner

(see Cleaning and Mainte-

nance, page 22)

2. Replace gas regulator

1. Problem will stop after a few

hours of operation

1. Turn control knob to LO

position and let warm up for

a minute

2. Operate burner until air is

removed from line. Have gas

line checked by local propane/

LP gas company

3. Observe minimum installation

clearances (see Figures 7 and

8, page 9)

4. Clean burner (see Cleaning

and Maintenance, page 22)

or replace burner orifice

1. Turn heater off when using

furniture polish, wax, carpet

cleaners or similar products

Advertising
This manual is related to the following products: