Inspecting burner, Operating fireplace – Desa CGCFTP User Manual

Page 21

Advertising
background image

www.desatech.com

111044-01F

21

OPERATING FIREPLACE

Continued

Thermocouple

Pilot Burner

Figure 32 - Correct Pilot Flame Pattern

(Propane/LP Shown)

Figure 33 - Incorrect Pilot Flame Pattern

(Propane/LP Shown)

Thermocouple

Pilot Burner

Note:

The pilot flame on natural gas units will

have a slight curve, but flame should be blue and

have no yellow or orange color.

Figure 34 - Correct Burner Flame Pattern

Figure 35 - Incorrect Burner Flame

Pattern

BURNER FLAME PATTERN

Figure 34 shows a correct burner flame pattern.

Figure 35 shows an incorrect burner flame pattern.

The incorrect burner flame pattern shows sporadic,

irregular flame tipping. The flame should not be

dark or have an orange/reddish tinge.
Note:

When using the fireplace the first time, the

flame will be orange for approximately one hour

until the log cures.
If burner flame pattern is incorrect, as shown in

Figure 35
• turn fireplace off (see To Turn Off Gas to Ap-

pliance, page 20)

• see Troubleshooting, page 23

THERMOSTAT

CONTROL OPERATION

The thermostatic control used on this fireplace

differs from standard thermostats. Standard

thermostats simply turn on and off the burner.

The thermostat used on this fireplace senses the

room temperature. The thermostat adjusts the

amount of gas flow to the burner. This increases

or decreases the burner flame height. At times

the heater will cycle back on when room tem-

perature drops below the set temperature.

The control knob can be set to any heat level

between HI and LO.
Note:

The thermostat sensing bulb measures

the temperature of air near the fireplace

cabinet. This may not always agree with

room temperature (depending on housing

construction, installation location, room size,

open air temperatures, etc.). Frequent use of

your fireplace will let you determine your own

comfort levels.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting

Instructions, page 20.

2. With control knob pressed in, strike match.

Hold match to pilot until pilot lights.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow step 8 under

Lighting Instructions, page 20.

INSPECTING BURNER

Check pilot flame pattern and burner flame pat-

tern often.

PILOT FLAME PATTERN

Figure 32 shows a correct pilot flame pattern.

Figure 33 shows an incorrect pilot flame pattern.

The incorrect pilot flame is not properly heating the

thermocouple. This will cause the thermocouple to

cool. When the thermocouple cools, the fireplace

will shut down.
If pilot flame pattern is incorrect, as shown in

Figure 33
• turn fireplace off (see To Turn Off Gas to Ap-

pliance, page 20)

• see Troubleshooting, page 23