Installation, Continued – Desa FPVF33NR User Manual

Page 10

Advertising
background image

105270-01G

For more information, visit www.desatech.com

For more information, visit www.desatech.com

10

INSTALLATION

Continued

INSTALLATION

Built-In Fireplace Installation

Actual

Framing

Height

32

3

/

8

"

33"

Front Width

34

5

/

16

"

35

1

/

2

"

Depth

16

11

/

16

"

17

3

/

4

"

BUILT-IN FIREPLACE INSTALLATION FOR
MODELS VYGF33PRA & VYGF33NRA

Built-in installation of this fireplace involves installing fireplace
into a framed-in enclosure. This makes the front of fireplace flush
with wall. If installing a mantel above the fireplace, you must follow
the clearances shown in Figure 20,

page 12. Follow the instructions

below to install the fireplace in this manner.

1.

Frame in rough opening. Use dimensions shown in Figure 13
for the rough opening.If installing in a corner, use dimensions
shown in Figure 14 for the rough opening. The height is 33"
which is the same as the wall opening above.

2.

If using blower, install and properly ground GA3555, three-
prong 120 volt electrical outlet, in fireplace. Follow instruc-
tions included in kit (see Accessories, pages 34 and 35).

3.

Install gas piping to fireplace location. This installation includes
an approved flexible gas line (if allowed by local codes) after
the equipment shutoff valve. The flexible gas line must be the
last item installed on the gas piping. See Installing Gas Piping
to Fireplace Location,
pages 12 and 13.

4.

Carefully set fireplace in front of rough opening with back of
fireplace inside wall opening.

5.

Plug electrical cord into electrical outlet installed in step 2.

6.

Carefully insert fireplace into rough opening.

7.

Attach flexible gas line to gas supply. See Connecting Fire-
place to Gas Supply,
pages 13 and 14.

8.

Attach fireplace to wall studs using nails or wood screws
through holes in nailing flange (see Figure 15).

9.

Check all gas connections for leaks. See Checking Gas Con-
nections
, pages 14 and 15.

10. Install brass trim after final finishing and/or painting of wall

(see Figure 7, page 8).

WARNING: A qualified electrician must connect

electrical wiring to duplex outlet for built-in installa-
tion. Follow all local codes.

BUILT-IN FIREPLACE INSTALLATION FOR
MODELS FPVF33PR & FPVF33NR

Built-in installation of this fireplace involves installing fireplace
into a framed-in enclosure. This makes the front of fireplace flush
with wall. If installing a mantel above the fireplace, you must follow
the clearances shown in Figure 20,

page 12. Follow the instructions

below to install the fireplace in this manner.

35

1

/

2

"

17

3

/

4

"

33"

Figure 13 - Rough Opening for Installing in Wall

Actual

Framing

Height

32

3

/

8

"

33"

Front Width

34

5

/

16

"

35

1

/

2

"

Depth

16

11

/

16

"

17

3

/

4

"

39

3

/

8

"

27

7

/

8

"

55

5

/

8

"

35

1

/

2

"

Figure 14 - Rough Opening for Installing in Corner (for Models
VYGF33NRA & VYGF33PRA only)

Figure 15 - Attaching Fireplace to Wall Studs (VYGF33PRA
Shown)

Nailing Flanges

Nails or
Wood
Screws

Advertising