Cleaning and maintenance, Specifications, Wiring diagram – Desa FPVF33NR User Manual

Page 22: Continued

Advertising
background image

105270-01G

For more information, visit www.desatech.com

For more information, visit www.desatech.com

22

LOGS

• If you remove logs for cleaning, refer to Installing Logs, pages

15 and 16, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the fireplace run-
ning. All slotted burner flame holes should be open with yellow
flame present. All round burner flame holes should be open with a
small blue flame present. Some burner flame holes may become
blocked by debris or rust, with no flame present. If so, turn off
fireplace and let cool. Remove blockage. Blocked burner flame
holes will create soot.

Figure 48 - Pilot Inlet Air Hole

Burner
Tube

Pilot
Assembly

Pilot Air
Inlet Hole

Ports/Slots

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole (Cont.)
Logs
Main Burner

WIRING DIAGRAM
SPECIFICATIONS

5.

Blow air into the primary air holes on the injector holder.

6.

In case any large clumps of dust have now been pushed into
the burner repeat steps 3 and 4, page 21.

Clean the pilot assembly also. A yellow tip on the pilot flame
indicates dust and dirt in the pilot assembly. There is a small pilot
air inlet hole about two inches from where the pilot flame comes
out of the pilot assembly (see Figure 48). With the unit off, lightly
blow air through the air inlet hole. You may blow through a
drinking straw if compressed air is not available.

CLEANING AND
MAINTENANCE

Continued

SPECIFICATIONS

VYGF33NRA
FPVF33NR

Btu (Variable)

20,000/30,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

Minimum*

5"

Shipping Weight

122 lbs.

* For input adjustment

VYGF33PRA
FPVF33PR

Btu (Variable)

20,000/33,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

8.0" W.C.

Inlet Gas Pressure (in. of water)

Maximum

14"

Minimum*

11"

Shipping Weight

122 lbs.

* For input adjustment

AUT

O

OF

F

ON

Thermopile

WIRING DIAGRAM

Note

: For proper operation of optional accessories, the wires from

the switch to the control must be connected exactly as shown.

Advertising