Adjusting the input level, Selecting the reference clock, 4 − basic operations – Teac DV-RA1000HD User Manual

Page 28

Advertising
background image

4 − Basic operations



TASCAM DV-RA1000HD

Adjusting the input level

The input level is adjustable for all inputs (analog or
digital), regardless of the current selection.

The balance between the left and right channels of the
input may also be set.

For optimum sonic quality, it is also possible to bypass
the input level and balance circuitry.

1

Press the

INPUT LEVEL

key to bring up the input

level screen:

Figure 4.19: Input level settings

2

Use the

F3

and

F4

keys to move between the

MAIN

(input level),

BALANCE

(between left and right) and

BYPASS

sections of the display.

Use the

JOG/DATA

dial to adjust the settings,

including the bypass setting.

TIP

Use the

F1

key to reset the input level to unity

gain, and the

F2

key to center the balance set-

ting.
You can adjust the analog input level to one of
the  stages in the range of –
through +1 dB,

and the digital input level in steps of 0. dB in the
range of –10 dB through +10 dB.

3

Press

ENTER

when finished.

NOTE

When the signal on playback or recording is at –
0.1 dBFS or over for more than one sample, the
OVER indicator on the meter lights. If a track is
normalized to –0.1 dB (for example) on a DAW be-
fore recording at unity gain on the DV-RA1000HD,
the OVER indicators may therefore light, even
though there is no clipping taking place.
You can set the meter release time and peak hold
mode in the preference screen. (See “General
preferences” on page .)
To reset the peak indication, press the

CANCEL

key while the home screen is displayed.

Selecting the reference clock

As mentioned earlier, only one clock sync source
should be available within a system.

The current clock selection is always shown on the
home display.

To select the clock source for the DV-RA1000HD:

1

Press the

MENU

key, and use the

JOG/DATA

dial

to select

SYSTEM SETUP

. Press

ENTER

.

2

Use the

JOG/DATA

dial to select

REFERENCE CLOCK

.

Press

ENTER

.

Figure 4.20: Word sync selection

3

Use the

JOG/DATA

dial to select the clock source

(

SOURCE

):

Internal

—the DV-RA1000HD acts as the

clock master.

Word

—the clock sync is received from the BNC

WORD SYNC IN

connector.

Digital IN

—the clock is received from the

currently selected digital audio input source.

NOTE

You cannot select

Digital IN

if the

DV-RA1000HD is playing or recording a project in
DSD mode.

4

Press

ENTER

to confirm the setting and return to

the system setup menu.

Advertising