Teac SX-1:SX-1LE Documentation Sony P2 Protocol User Manual

Page 5

Advertising
background image

From Controlling device

Return from SX-1

Command

CMD 1 CMD 2 DATA

NAME

CMD1 CMD 2 DATA

TIMER-1 PRESET

44

00

*5

ACK

10

01

*1

EDIT PRESET

41

30

*11

ACK

10

01

*6

TAPE/AUTO SELECT

41

32

XX

ACK

10

01

*1

SERVO REF SELECT

41

33

XX

ACK

10

01

*1

HEAD SELECT

41

34

XX

ACK

10

01

*1

COLOR FRAME SELECT

41

35

XX

ACK

10

01

*1

TIMER MODE

41

36

XX

ACK

10

01

*1

EDIT FIELD SELECT

41

3A

*16

ACK

10

01

CURRENT TIME SENSE

61

0C

*15

TIMER-1 DATA

74

00

TIMER-2 DATA

74

01

LTC TIME DATA

74

04

LTC TIME&UB DATA

78

04

LTC UB DATA

74

05

VITC TIME DATA

74

06

VITC TIME&UB DATA

78

06

VITC UB DATA

74

07

LTC INTERPOLATED

74

14

TIME DATA
LTC INTERPOLATED

78

14

TIME&UB DATA
VITC HOLD TIME DAT 74

16

VITC HOLD TIME &

78

16

UB DATA

STATUS SENSE

61

20

STATUS DATA

7x

20

*13

EDIT PRESET SENSE

61

30

EDIT PRESET DATA

7x

30

*14

TIMER MODE SENSE

60

36

TIMER MODE

71

36

00

Unsuported Commands

XX

YY

NAK

11

12

*12


Notes:


*1 Command is acknowledged, but no action is taken.

*2 The SX-1 can selectively reply to this command, set in the LCD Preferences screen,
TRANSPORT page.

F01A TASCAM HDR Series (Default)
6003 Sony 3324S
101C Sony BVU950

This reply data is also affected by the Frame Rate setting of the currently loaded project.

4

Advertising