Usdt 3002, Operation, 1 pushbuttons for adjustment – Thermo Technologies USDT 3002 User Manual

Page 6: 2 system monitoring display

Advertising
background image

USDT 3002

© 06279 usdt_3002.mon

us.ind

d

|

6

1

3

2

backwards

forward

SET

(selection / adjustment mode)

The system monitoring display consists of 3 blocks: indica-
tion of the channel,
tool bar and system screen (active
system scheme).

The indication channel consists of two lines. The upper
line is an alphanumeric 16-segment indication. This displays
the channel names / menu items. In the lower 7-segment
indication, the channel values and the adjustment parameter
are indicated.
Temperatures and temperature differences are indicated
in or .

2.2.1 Channel indication

only channel indication

2.2.2 Tool bar

The additional symbols of the tool bar indicate the current
system status.

only tool bar

2. Operation

2.1 Pushbuttons for adjustment

The controller is operated by the 3 buttons below the
display.

The forward-key (1) is used for scrolling forward

through the indication menu or to increase the adjustment
values. The backwards-key (2) is accordingly used for the
reverse function.

Select a channel channel using the forward/back keys (1
and 2). Briefly press the center key, so that „SEt“ flashes
Adjust the value using the foward/back keys
then briefly press the center key, so that „SEt“
permanently appearsThe adjusted value is now saved.

Additional channels (i.e. manual operation of pump,
activation of 2nd relay, cooling etc.) become available by
holding down the forward key (1) for two seconds

2.2 System monitoring display

!

Complete Monitoring-Display

Symbol

standard

flashing

relay 1 active

relay 2 active

maximum tank temperature
active / maximum tank
temperature exceeded

collector cooling function or

reccoling function active

antifreeze- function activated

collector minimum limitation
or antifreeze function active

collector security shutdown or
tank securtiy shutdown active

+

sensor defect

+

manual operation active

an adjustment channel is
changed SET-mode

Advertising