3. Activating the Operating System

User has the option of a one or two relay system

1

3

2

backwards

forward

SET

(Selection / Adjustment mode)

Operation cont-
rol lamp

Arr 1

Arr 2

1. AC power supply must be activated. The controller passes
an initialisation phase in which the operating control lamp
flashes red and green. At this point the controller is in au-
tomatic operation with factory settings.

Arr 1. Controller is ready for operation o the user may
activate the 2nd relay:

2. - Arr 2: Extended Solar System (with second relay)

-locate Arr by holding down forward key for 2 seconds

-press center key to begin set

-increase to Arr 2 using forward key

-press center key to save adjustment

Now the controller is ready for operation.

4. Controller parameter and indication channels

4.1 Channel-overview

Legend:

x

Corresponding channel is available.

x*

Corresponding channel is available if the appropriate option
is activated.

Corresponding channel is only available if the option heat
quantity measurement is activated (OWMZ).

MEDT

The channel antifreeze content (MED%) is only shown if a
medium other than water or Tyfocor LS / G-LS (MEDT
0 or 3)
is used. The adjustment is only appropriate when
using other types of antifreeze.

Corresponding channel is only available if the option heat
quantity measurement is deactivated (OWMZ).

Please note:

S3 and S4 are only indicated if sensors are connected.

channel

Arr

specification

page

1

2*

COL

x

x

Temperature collector 1

9

TST

x

Temperature tank 1

9

TSTL

x

Temperature tank 1 below

9

TSTU

x

Temperature tank 1 above

9

S3

x

Temperature sensor 3

9

TRF

Temperature return sensor

9

S4

Temperature sensor 4

9

h P1

x

Operating hours relay 1

9

h P2

x

Operating hours relay 2

9

kWh

Heat quantity kWh

10

MWh

Heat quantity MWh

10

Arr

1-2

System

8

DT O

x

x

Switch-on temperature difference

10

DT F

x

x

Switch-off temperature difference

10

S MX

x

x

Maximum temperature tank 1

10

EM

x

x

emergency temperature collector 1

10

channel

Arr

specification

page

1

2*

OCX

x

x

Option collector cooling collector 1

11

CMX

x*

x*

Maximum temperature collector 1

11

OCN

x

x

Option minimum limitation collector1

11

CMN

x*

x*

Minimun temperature collector 1

11

OCF

x

x

Option antifreeze collector 1

11

CFR

x*

x*

Antifreeze temperature collector 1

11

OREC

x

x

Option reccoling

11

O TC

x

x

Option tube collector

12

AH O

x

Switch-on temp. for thermostat 1

12

AH F

x

Switch-off temp. for thermostat 1

12

OHQM

x

x

Option WMZ

12

FMAX

Maximum flow

12

MEDT

Antifreeze type

10

MED%

MEDT MEDT Antifreeze content

10

HND1

x

x

Manual operation relay 1

12

HND2

x

x

Manual operation relay 2

12

LANG

x

x

Language

12

UNIT

x

x

Change over °FAH / °CEL

12

PROG

XX.XX

Program number

VERS

X.XX

Version number