5 dry contact alarm – Thinklogical Q-4300 Video Modules Manual User Manual

Page 22

Advertising
background image

®

Q - S e r i e s V i d e o M o d u l e s P r o d u c t M a n u a l , R e v . I

Page 22

4.4.9.

Adapters: RJ45 to DB9F (ADP-000025), RJ45 to DB9M (ADP-000019)

RJ45 to

DB9F ADPT

ADP-000025

RJ45 to

DB9M ADPT
ADP-000019

4.4.10.

The USB Mini-B to USB-A User Configuration Control Cable (CBL000105-

002MR), for use with scaler models housed in a Q-1300 Chassis, is available
from Thinklogical. Please contact your sales representative.

USB Mini-B

USB A


4.5 Dry Contact Alarm

Dry contact alarms are located on each of the individual modules. The relay is energized when there is
an alarm condition, such as over temperature or power regulation.

Normally Closed

Common

Normally Open

ALARM

The dry contact alarm is a Form C contact with the following ratings:

Nominal switching capacity: 1A, 30V DC
Max. switching power: 30W DC

Dry Contact Alarm Receptacle