6 set-up, 1 dry contact alarm, 2 firmware upgrades – Thinklogical Velocitykvm Desktop Manual User Manual

Page 13

Advertising
background image


Revision A

13

October 2011

2.6

Set-Up

2.6.1 Dry Contact Alarm

Dry contact alarms are located on the transmitter and receiver modules. When there is an alarm
condition the relay is energized. Examples of possible alarm causes might be over-temperature or a
power supply issue.

NORMALLY CLOSED

NORMALLY OPEN

COMMON

ALARM

The dry contact alarm is a Form C contact with the following ratings:

Nominal Switching Capacity:

1 A 30 VDC, 0.3 A 125 VAX (resistive load)

Max. Switching Power:

30 W (DC), 37.5 VA (AC) (resistive load)

2.6.2 Firmware Upgrades

Firmware upgrades are available through Thinklogical

®

. Please call for technical assistance at:

1-203-647-8700.

Advertising