2.6.1

Rear Panel Views

Transmitter/Transmitter: STM-L1L1X2-LCTX

Receiver/Receiver: STM-C1C1X2-LCRX

Transmitter/Receiver: STM-L1C1X2-LCTR

STM Modules in Transmitter, Receiver and Transceiver Configurations

2.6.2 T-4200 Chassis SDI Module Options

STM-L1L1X2-LCTX

T-4200 SDI Dual Transmitter Module: 2 Inputs (with 2 Loop Outs) & 2 SFPs

STM-C1C1X2-LCRX

T-4200 SDI Dual Receiver Module: 2 SFPs & 2 Pairs of SDI Outputs

STM-L1C1X2-LCTR

T-4200 SDI Transceiver Module, TX: 1 Input with Loop Out & 1 SFP

RX: 1 SFP & 2 SDI Outputs

2.7 Set-Up

2.7.1 Dry Contact Alarm

Dry contact alarms are located on the transmitter and receiver modules

’ rear panels. When there is an

alarm condition, the relay is energized. An example of possible alarm causes might be over-temperature
or a power supply issue.

NORMALLY CLOSED

NORMALLY OPEN

COMMON

ALARM

The dry contact alarm is a Form C contact with the following ratings:

Nominal Switching Capacity:

1 A 30 VDC, 0.3 A 125 VAX (resistive load)

Max. Switching Power:

30 W (DC), 37.5 VA (AC) (resistive load)