Xsyncstatus – Thinklogical Router - ASCII-API User Manual
Page 14
XSTATUSIO - return switch status as pairs of ports, input first
upper chassis ports listed first, then a ';', then lower
chassis ports
Iiiiiooooiiiioooo...;iiiiooooiiiioooo...
XSTATUSOI - return switch status as pairs of ports, output first
upper chassis ports listed first, then a ';', then lower
chassis ports
Oooooiiiiooooiiii...;ooooiiiiooooiiii...
XOPTIONS - returns a bit mask of installed options
bit 0 HDX Sync card compatable (lsb)
bit 1 XTEST2 allowed
bit 2 upper case commands only
bit 3 XMAXCARDS returns the total number of cards allowed,
not one-half the number
bit 4 Router supports point-to-point connection mode
XQUIT - end this session
XHELP - this text
XSYNCSTATUS
Valid in the HDX family of routers, it returns the status of the sync card. This command is not allowed in the Vx family
of routers and it will return an error.
Format:
XSYNCSTATUS
Example Results:
R0007ERnnnn
R0032OKi,r,l,a,format,reference (Ex: R0020OK1,0,0,0,0063,0003)
i = 1: sync card is installed
r = 1: reference detected
l = 1: locked
a = 1: auto, = 0: manual
format = output sync format index
reference = input reference format index
Jun 12, 2014
Router ASCII API: V4.5-1
13/33