Error and Status Codes

1.1

0001 – Syntax error.

1.2

0002 – The command is missing an input port field.

1.3

0003 – The command is missing an output port field.

1.4

0004 – The command has multiple input fields, but only 1 is allowed.

1.5

0005 – The command has multiple output fields, but only 1 is allowed.

1.6

0006 – The input port value is out of range.

1.7

0007 – The output port value is out of range.

1.8

0008 – The command contains an invalid character.

1.9

0009 – A port value of 9999 is not allowed in this command.

1.10

0010 – A SNMP error occurred (only a DCS switch will generate this error).

1.11

0011 – An error occurred while attempting an internal fork command.

1.12

0012 – API received a command that is not allowed.

1.13

0013 – Not enough memory to process the command

1.14

0014 – File I/O error; an error occurred while reading or writing a file.

1.15

0015 – The VxRouter control process is not responding.

1.16

0016 – The command references multiple chassis, but the router only has one.

1.17

0017 – A macro was sent with a semi-colon ';', but the router is uni-directional. Uni-directional routers

do not allow port numbers after a semi-colon.

1.18

0018 – Partition or Restrictive port failure.

1.19

0019 – The connection can not be made because of a blocking condition in the internal switch matrix.

Error 10:

This is only generated by a DCS switch.

Error 11, 13, 14, 15:

An internal program error: Contact Thinklogical if you get this message.

Error 12:

API V4 does not use this error code.