Operating heater – Desa VF-30N-PJD User Manual

Page 16

Advertising
background image

www.desatech.com

111826-04C

16

Changing The Code

The control is radio frequency operated. A code

(chosen from among 4,000 available codes)

is preset for all valves, but can be changed

if required (15 additional codes available).

Change DIP switch position. (The DIP switch

is located inside the hand held control at the

top of the battery compartment.) Then press the

receiver's reset button until you hear a second

(longer) signal. When pressing the button

on the remote handset in the following 20 sec.,

the receiver learns the new code.
Shut-off Procedure

To save battery power; press to turn main

gas to pilot gas. Press OFF button to shut off

the device including pilot flame. The device can

be shut off with ON/OFF switch, thus disabling

the remote hand set.
Setting The Display ( °C/24h and °F /12h)

Press and hold OFF and

until display

changes from °F (and 12 hour clock) to °C (and

24 hour clock) or vice versa.
Setting The Time

• After connecting the battery or by simulta-

neously pressing and the display will

start to flash. You are in the set mode.

• From SET mode press to set the hour and

to set the minute.

• Wait or press OFF to return to the manual

mode.

Battery Replacement

Remote handset battery needs to be changed

when LED is dim. Battery life expectancy is 2

to 3 years. Replacement is recommended at the

beginning of heating season. Battery needs to be

changed when acoustic error message appears

during ignition (see Identifying Error Signals

from Receiver on page 23).
Changing Mode of Operation

• Press the SET button quickly to change the

mode of operation in the following order:

MAN, TEMP, TEMP, TIMER.

• Manual flame height adjustment (MAN ap-

pears on display): Press to turn on the fire

(main burner) or to increase flame height.

Press to decrease flame or to go down

to pilot only. The receiver acknowledges the

transmission with an acoustic signal.

• The day time temperature mode ( TEMP ap-

pears on display): The sensor in the transmitter

measures room temperature. The controller

compares the room temperature with set tem-

perature and sends a signal to the receiver to

turn the gas valve motor up or down, to adjust

the flame height accordingly.

• The nighttime setback temperature (

TEMP

appears on display): The sensor in the

transmitter measures the temperature and

adjusts it according to the nighttime setback

temperature. There is a bigger temperature

differential during this cycle.

• Timer: The timer mode ( TIMER ) operates

much like the temperature mode above. The

timer setting allows you to set specific times

for on and off. (There are 2 burner on and

2 burner off cycles every 24 hours.) If the

reading for the nighttime temp. is "– – –",

the motor will turn off the valve to standby

pilot position and wait for the next burner

on cycle. This display shows the setting tem-

perature every 30 seconds.

Setting the Temperature

• Select the desired mode of operation (day or

night) by pressing the SET button briefly.

• Hold the SET button until the display

flashes.

• Set the temperature with the or (40°F

is the minimum temperature).

• Wait or press OFF to go to temperature

control mode.

• If temperature control in moon times should

be off (lower battery consumption), decrease

the night temperature until "– – –" appears

on display.

OPERATING HEATER

Continued

SET

OFF

STAND

BY

Figure 16 - Control Panel for Hand-Held

Remote

Advertising