Installation – Desa VF-30N-PJD User Manual

Page 9

Advertising
background image

www.desatech.com

111826-04C

9

INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION

WARNING: Maintain the

minimum clearances. If you can,

provide greater clearances from

floor, ceiling and adjoining wall.

INSTALLATION

Continued

Carefully follow the instructions below. This will

ensure safe installation into a masonry, UL127-

listed manufactured fireplace or listed vent-free

firebox enclosure.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling

A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace cabinet (see Figure 4).

Note: When installing your gas logs into

a manufactured firebox, follow firebox

manufacturer’s instructions for minimum

clearances to combustible materials.

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 42 inches.

Figure 4 - Minimum Clearance for

Combustible to Wall

*Minimum 16 inches from Side Wall

*

Example

LOG SIZING REQUIREMENTS

Minimum Firebox Size

Log

Front

Rear*

Size Height

Depth

Width

Width

18"

1"

14"

24"

20"

24"

1"

14"

28"

22"

30"

24"

1

1

/

2

"

42"

28

3

/

4

"

MINIMUM FIREPLACE

CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

18", 24", 30"

Side Wall

16"

Ceiling

42"

Floor

5"

*Measured at 14" depth

Minimum Noncombustible Material
Clearances
If Not Using Mantel
Note:

If using a mantel, proceed to If Using

Mantel. If not using a mantel, follow the informa-

tion below.

You must have noncombustible material(s) above

fireplace opening. Noncombustible materials

(such as slate, marble, tile, etc.) must be at least

1/2 inch thick. With sheet metal, you must have

noncombustible material behind it. Noncombus-

tible material must extend at least 8" up (for all

models). If noncombustible material is less than

12", you must install the fireplace hood accessory

24" and 30" models only). See Figure 5, page 10,

for minimum clearances.
If Using Mantel
You must have noncombustible material(s) above

the fireplace opening. Noncombustible materials

(such as slate, marble, tile, etc.) must be at least

1/2 inch thick. With sheet metal, you must have

noncombustible material behind it. Noncombus-

tible material must extend at least 8 inches up (for

all models). If noncombustible material is less than

12", you must install the fireplace hood accessory.

Even if noncombustible material is more than 12",

you may need the hood accessory to deflect heat

away from your mantel shelf. See Figures 5, 6 and

7, page 10, for minimum clearances.

Advertising