Troubleshooting – Desa VF-30N-PJD User Manual

Page 20

Advertising
background image

www.desatech.com

111826-04C

20

TROUBLESHOOTING

WARNING: Turn off heater and let cool before servicing. Only a

qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note:

All troubleshooting items are listed in order of operation.

POSSIBLE CAUSE

1. Ignitor electrode not con-

nected to ignitor cable

2. Ignitor cable pinched or wet

3. Broken ignitor cable

4. Bad piezo ignitor

5. Ignitor electrode positioned

wrong or broken

6. Bad module

1. Gas supply turned off or equip-

ment shutoff valve closed

2. Control knob not in PILOT

position

3. Control knob not pressed in

while in PILOT position

4. Air in gas lines when in-

stalled

5. Depleted gas supply (pro-

pane/LP only)

6. ODS/pilot is clogged

7. Gas regulator setting is not

correct

8. Bad module

1. Inlet gas pressure is too low

2. Burner orifice(s) clogged

3. Burner orifice(s) diameter is

too small

4. Wire disconnected from gas

control

5. Bad module

1. Manifold pressure is too low

2. Burner orifice(s) clogged

OBSERVED PROBLEM

When

and are pressed

at the same time, there is no spark

at ODS/pilot

When

and are pressed,

there is spark at ODS/pilot but

no ignition

Burner does not light after pilot

is lit

Delayed ignition burner

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched

by any metal or tubing. Keep

ignitor cable dry

3. Replace ignitor cable

4. Replace piezo ignitor

5. Replace pilot assembly

6. Replace module

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while in

PILOT position

4. Continue holding down con-

trol knob. Repeat igniting op-

eration until air is removed

5. Contact local propane/LP gas

company

6. Clean ODS/pilot (see Cleaning

and Maintenance, page 19) or

replace ODS/pilot assembly

7. Replace gas regulator

8. Replace module

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner (see Cleaning

and Maintenance, page 19) or

replace burner orifice(s)

3. Replace burner orifice(s)

4. Reconnect leads (see Wiring

Diagram, page 24)

5. Replace module

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner (see Cleaning

and Maintenance, page 19) or

replace burner orifice

Advertising