Wallmount installation, Using adhesive strips, Using screws – Verilink DDS Lite (34-00295.C) Product Manual User Manual

Page 12: Connections, Dds network connection, Using adhesive strips using screws, Network connection, Supplied materials

Advertising
background image

6

C

HAPTER

2: I

NSTALLATION

AND

C

ONFIGURATION

Supplied
Materials

The Multi-Rate DDS CSU/DSU is shipped from the factory
with the following standard equipment.

external AC power supply

reference manual

adhesive strip

phone cable

Wallmount
Installation

Using Adhesive Strips

1 Select a place close to a 115 VAC outlet with clearance for the

signal and power cables. The indicators and switches should be
easily accessible.

2 Verify the mounting surface is clean.

3 Cut the adhesive strip to the desired length and affix the backing

of one piece to the underside of the unit.

4 Attach the other adhesive strip to the piece on the underside of

the unit.

5 Remove the backing to expose the sticky surface.

6 Press the underside of the unit firmly against the selected place.

Using Screws

1 Select a place close to a 115 VAC outlet with clearance for the

signal and power cables. The indicators and switches should be
easily accessible.

2 Vertically place two #6 screws 3-13

32 inches apart at the

selected place. Leave the screws out about an eighth of an inch.

3 Place the upright unit over the screws until the holes engage and

slide the unit down until it locks.

Connections

The Multi-Rate DDS CSU/DSU has three interface connectors:
an RJ- 48C DDS network connector, a 3-pin power connector,
and an RS-232 connector.

DDS

Network

Connection

The network DDS facility
interface is a standard
RJ- 48C (8 -pin) modular
jack with the following
pinout.

Table 2-1 DDS Network Connection

Pin

Assignment

1

Network Transmit Out

2

Network Transmit Out

3 – 6

Not Used

7

Network Data In

8

Network Data In