Warnings – Verilink SNMP Management (No Part Number) Product Manual User Manual

Page 12

Advertising
background image

SNMP Management

SNMP-12

Verilink SNMP

Status {manditory, not manditory}

Syntax {specifies values allowed by the object}

Description {provides explanation}

Summary: For information on managing any specific module, use
the table above to access the specific file and determine the
information you need.

Warnings

The warnings are grouped according to the modules affected. Read
this section before using the modules. The only AS3000 module
listed is the SCM.

SCM and NCM

1. Before building circuits or performing any other configuration,

go to the Node Administration Menu to set the shelf type.

NOTE: If the shelf type is not set before building the circuits or configuring

modules, problems may occur with the circuit or configuration

databases.

2. The read and write community strings should be set correctly

to access the node via SNMP.
When configuring the community strings, restrict each string
setting to 30 characters or less. The current Craft interface
does not protect against inadvertent insertion of strings larger
than 30. Such a string insertion may cause unpredictable
results.

3. Circuit build is not supported via SNMP for TABS modules.

IDCSU

For the IDCSU loopback configuration:

1. There is a DTE and a Net port.

2. In the display that comes up for ncmidcsuDiagnosticEntry,

only SNMP line 1 is valid for objects ncmidcsuLoopback and
ncmdteloops. These objects are not valid in line 2.

3. To configure DTE loopbacks, use ncmdteloops, entry 1.

4. The following object options are displayed under

ncmidcsuLoopback but are not valid (the MIB will not be
modified):

• repeater-Loop-Back

• csu-Equip-Loop-Back

• deactivate-ELB-and-RLB