Verilink SNMP Management (No Part Number) Product Manual User Manual

Page 6

Advertising
background image

SNMP Management

SNMP-6

Verilink SNMP

NOTE: To determine the clock source for Verilink products, see the Verilink

enterprise MIBs.

Table 5 DS1 Near End Group 2

dsx1LoopbackConfig Access is read-write:

• dsx1NoLoop(1) if no loopback is in progress.

• dsx1PayloadLoop (2) if near-end Payload Loopback (PLB) is

enabled.

• dsx1LineLoop(3) if near-end Line Loopback (LLB) is enabled.

For “read”:

• dsx1OtherLoop(4) for loopbacks that are not defined in this

object.

For “read”:

• dsx1OtherLoop(4) if RLB is enabled.

dsx1LineStatus

dsx1NoAlarm(1) if no alarm present.

dsx1RcvFarEndLOF(2) if far-end LOF (Yellow Alarm).

dsx1RcvAIS(8) if far-end AIS.

dsx1LossOfFrame(32) if near-end LOF (Red Alarm).

dsx1LossOfSignal(64) if near-end LOS.

dsx1LoopbackState(128) if near end is looped.

dsx1OtherFailure(4096) if near-end BER exceeded.

dsx1RcvFarEndLOF and dsx1RcvAIS are supported

for AS2000 equipment.

dsx1SignalMode

Access is read only.

none(1) - indicates that no bits are reserved for

signaling on this channel.

dsx1TransmitClock

Source

Access is read-only.

loopTiming(1) if NET timing is selected.

localTiming(2) if internal (INT) timing is selected.

throughTiming(3) if THROUGH timing is selected.

dsx1Fd1

Access is read-only.

dsx1Ansi-T1-403(2) is always on.

dsx1Att-54016(4) is always on.

Object-Type

Parameters

Object-Type

Parameters

dsx1CurrentIndex

A number calculated with the formula in

Calculating

the

SNMP

ifIndex

,

on page 2.

dsx1CurrentSESs

The number of Severely Errored Seconds in the

current 15-minute interval.

dsx1CurrentSEFSs

The number of Severely Errored Framing Seconds in

the current 15-minute interval.

dsx1CurrentESs

The number of Errored Seconds in the current 15-

minute interval.

dsx1CurrentUASs

The number of Unavailable Seconds in the current

15-minute interval.

dsx1CurrentCSSs

0 (Not supported).

dsx1CurrentPCVs

0 (Not supported).

Advertising