Local loop/error inject button, Remote loop button, Bert button – Verilink WANsuite 5650 (34-00314.E) Product Manual User Manual
Page 16: Led indicators, Led indicators -4

1-4
W A N s u i t e 5 6 5 0
initiate/terminate tests and the corresponding LEDs indicate the status of tests
on this port only.
When on the G.703 port selection, the
G.703
port LED flashes as an
indication. If there is only a single service on the G.703 port then the
LOCAL
LOOP/ERR INJ
and
REMOTE LOOP
buttons initiate/terminate tests and the
corresponding LEDs indicate the status of tests on this port only.
When on the SHDSL port selection, the
SHDSL
port LED flashes as an
indication. The
LOCAL LOOP/ERR INJ
and
REMOTE LOOP
buttons initiate/
terminate tests and the corresponding LEDs indicate the status of tests on this
port only. These tests are on the aggregate SHDSL payload.
The
REMOTE LOOP
button will invoke a G.SHDSL Network Side Transparent
Loop (see figure A.1).
Either the G.703 port or the Serial interface Nx64 will have transparent loop
with the
LOCAL LOOP
button (see figure A.2 or figure A.3).
NOTICE:
PORT SELECT will not operate if any locally initiated tests are in
progress.
Local Loop/Error Inject Button
Default: Enabled.
Remote Loop Button
Default: Enabled.
BERT Button
Default: Enabled.
LED Indicators
The table below describes the WANsuite 5650’s front panel LED indicators.
NOTICE:
The SHDSL, G.703, and Nx64 port LEDs will flash when selected by the
port select button
NOTICE:
When no port is selected (indicated by none of the port LEDs flashing),
only the PORT SELECT button is enabled.
NOTICE:
When no port is selected, the LL and RL LEDs display a summation of
the test states of the Nx64 (serial interface), G.703, and SHDSL ports.