Supervisory port, Power, Mechanical – Verilink WANsuite 5650 (34-00314.E) Product Manual User Manual
Page 62: Environmental, Alarms, Industry listings, Diagnostics

A-2
W A N s u i t e 5 6 5 0
Supervisory Port
Connection:
DB-9 female
Data Rates:
(bps) 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
(default: 38400 bps)
Protocols:
VT100
Power
Voltage Input:
100–240 VAC
Frequency:
50 or 60 Hz
Dissipation:
10 W maximum (34.15 BTU/hour)
Current:
200 mA maximum
Mechanical
Mounting:
Stand-alone
Weight:
2.13 lb. (0.97 kg)
Dimensions:
Width 8.36 in. (21.234 cm)
Height: 1.65 in. (4.191 cm)
Depth: 9.11 in. (23.139 cm)
Environmental
Operating Temp:
32° to 122°F (0° to 50°C)
Storage Temp:
-13° to 158°F (-25° to 70°C)
Humidity:
96% maximum (non-condensing)
Alarms
Activation:
Programmable thresholds on all interfaces
Reporting:
Via SHDSL EOC or local management port
Industry Listings
Compliance:
CISPR 22 Class B
Safety:
EN 60950 (1992)
Diagnostics
Performance:
15-minute and 30-day monitoring (sampled every second)
Network Loops:
Line loopback or maintenance loopback (see Figures A-1
and A-2)
NOTICE:
All the following loopback diagrams show the loops as if the unit is
configured as an STU-R. If the unit were configured as an STU-C, the
Network and Customer sides would be reversed.