OBSERVED PROBLEM

Log set produces a clicking/tick-

ing noise just after burners are lit

or shut off

Log set produces unwanted

odors

Gas odor even when control knob

is in OFF position

Gas odor during combustion

REMEDY

1. This is common with most

appliances. If noise is

excessive, contact qualified

service person

1. Open window to ventilate

room. Stop using odor causing

products while appliance is

running

2. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 8)

1. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 8)

2. Replace control valve or gas

control

1. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 8)

POSSIBLE CAUSE

1. Metal expanding while

heating or contracting while

cooling

1. Log set burning vapors

from paint, hair spray,

glues, cleaners, chemicals,

new carpet, etc. (See

IMPORTANT

statement

above)

2. Gas leak. See Warning

statement at top of
page

1. Gas leak. See Warning

statement at top of
page

2. Control valve or gas control

defective

1. Gas leak. See Warning

statement at top of
page

TROUBLESHOOTING

Continued

WARNING: If you smell gas

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Fol-

low the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

Operating log set where impurities in air exist may create odors. Cleaning supplies, paint,

paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These

fumes may mix with combustion air and create odors. These odors will disappear over time.