INSTALLATION

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping

and connections, internal and

external to unit, for leaks after

installing or servicing. Correct

all leaks at once.

WARNING: Never use an

open flame to check for a leak.

Apply a noncorrosive leak detec-

tion fluid to all joints. Bubbles

forming show a leak. Correct all

leaks at once.

PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)

1. Disconnect log set with its individual equip-

ment shutoff valve from gas supply piping

system.

2. Cap off open end of gas pipe where equipment

shutoff valve was connected.

3. Pressurize supply piping system by either us-

ing compressed air or opening main gas valve

located on or near gas meter.

4. Check all joints of gas supply piping system.

Apply noncorrosive leak detection fluid to gas

joints. Bubbles forming show a leak.

5. Correct all leaks at once.

6. Reconnect log set and equipment shutoff valve

to gas supply. Check reconnected fittings for

leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 5).

2. Pressurize supply piping system by either us-

ing compressed air or opening main gas valve

located on or near gas meter.

3. Check all joints from gas meter to equip-

ment shutoff valve (see Figure 6). Apply

noncorrosive leak detection fluid to all joints.

Bubbles forming show a leak.

4. Correct all leaks at once.

Figure 5 - Equipment Shutoff Valve

Equipment
Shutoff
Valve

Open

Closed

Figure 6 - Checking Gas Joints

HEARTH KIT ASSEMBLY AND
INSTALLATION

1. Determine which side the gas line will be

coming into the fireplace.

NOTICE: Unit comes preassembled with gas

inlet on right side. If your fireplace gas supply

is on the left, gas inlet should be repositioned

to left side of unit.

2. If gas supply line in your fireplace is on the right

side, continue to step 3. If not, see Reposition-

ing the Gas Inlet to the Left Side of Unit.

3. Install adapter fitting that comes with log set

into fireplace gas supply pipe (see Figure 7).

Seal using thread sealant.

Figure 7 - Connecting Adapter to Gas

Supply

Gas
Connector
Tube

Adapter
Fitting

Gas Inlet
Fitting

Equipment
Shutoff Valve

Gas Meter