7 troubleshooting – Watson-Marlow PD/40 User Manual

Page 17

Advertising
background image

17

7 TROUBLESHOOTING

If the pulsation damper does not function (correctly), consult the following checklist to see if you can
remedy the problem yourself. If you cannot, please contact your Bredel representative.

Problem

Possible cause

Solution

(Heavy) vibration of
Pump, Pulsation
damper or pipework

Pressure inside vessel
too low

Pressurize the vessel of pulsation
damper again according

paragraph

5.5 Setting the pulsation damper pressure
level for operation
.

Pressure inside vessel
too high

Product leakage

Not all parts have been
greased properly.

Grease all necessary parts. See also
paragraph 6.3 Replacing the pulsation
damper hose
.

Pressure loss at
pulsation damper
housing

Damaged O-ring (pos.
4 or 5)

Replace the O-ring concerned.

Pressing ring (pos. 7)
incorrectly mounted

Tighten to the specified torque settings
(see paragraph 8.2 Torque values)

Short pulsation
damper hose life

Chemical corrosion of
the hose

Check the compatibility of the hose
material with the product to be pumped.
Consult your Bredel representative for
correct hose selection.

High discharge
pressures

Maximum operating pressure is 1600 kPa.
Check whether the discharge line is
blocked. Make sure the shut-off valves are
fully opened and the pressure-relief valve
(if present) in the discharge line is
functioning properly.

High product
temperature

Consult your Bredel representative for
correct pulsation damper hose selection.

High pulsations

Restructure the discharge and inlet
conditions.

Advertising