8 specifications – Watson-Marlow PD/40 User Manual

Page 18

Advertising
background image

18

8 SPECIFICATIONS

8.1

General information

Description

Value

Maximum allowable pressure in vessel

2300 kPa

334 psi

Maximum allowable working pressure
discharge line before pulsation damper

1600 kPa

232 psi

Allowable ambient temperature

−20 to +45

°

C

−4 to +113 °F

Allowable product temperature

−10 to +80 °C

+14 to +176 °F

Allowable storage temperature

−40 to +70

°

C

−40 to +158 °F

Maximum surface temperature

+90 °C (T5)

+194 °F (T5)

Air volume vessel

See: identification plate

8.2

Torque values

Component

Description

Unit

PD/40

PD/65

PD/100

Pressing ring (pos. 7)

Thread

M115 x 2

M145 x 2

M185 x 3

Torque value

N/A

N/A

N/A

Toolbar diameter mm

Ø16

Ø16

Ø16

inch

Ø0.63

Ø0.63

Ø0.63

Hose clamp (pos. 8)

Thread

M8

M8

M10

Torque value

1)

Nm

12 - 25

15 - 35

15 - 35

lbf in 106 - 220

133 - 310

133 - 310

Key width

mm

13

13

17

inch

0.51

0.51

0.67

Connecting flange (pos. 11) Thread

M8

M10

M12

Torque value

Nm

25

50

85

lbf in 220

440

750

Key width

mm

13

17

19

inch

0.51

0.67

0.75

1) Minimum torque value based on new clamps with smooth thread.
See also chapter 6.3 Replacing the pulsation damper hose point 17 for extra instruction on hose
clamp installation.

Advertising
This manual is related to the following products: