Operator’s manual df32 – Watson-Marlow DF32 User Manual

Page 21

Advertising
background image

Operator’s manual
DF32

Rev.: 1.03 Date: 2007-03-12 Page 21 of 32

File:
DF32 OM 1.03 EN


F10: gives a current indication of the number of fills completed per minute.

The fills have not been calibrated. For this function, please see chapter 5 of this manual.

7.5 Stop

filling

When DF32 has completed the number of fills asked for in DF32: it will stop automatically.
If <GO> is pressed again, DF32 will complete the programmed number of fills once more.

If you want to stop the filling before the programmed number has been completed, press <STOP>,
and DF32 will stop after completing the filling in progress.
The filling series can be completed by pressing <GO>.

If you want to stop IMMEDIATELY, such as in the middle of a fill, press <STOP> twice, and DF32 will
stop immediately.

The filling series can be completed by pressing <disp.>+<GO>, and the interrupted filling will be
included.

7.6 Used as a pump

DF32 can also be used as a pump.

In this case only tube diameter and velocity should be entered.

Start the pumping by pressing <pump>+<GO>.

DF32 will start with the entered acceleration and run up to the required number of revolutions per
minute.

DF32 will pump at this velocity until stopped by pressing <STOP>.

7.7 Used with a bottle handling system

DF32 can also be used together with a bottle handling system like FlexFeed 20 from Flexicon.
When DF32 is integrated in an automatic bottle handling system, it is important to observe the
following:

The batch size in case of running with a bottle handling system must be set to 1.
The DF32 should be in dispense mode before starting the fill sequence.
The Go signal which activates filling should be generated by the bottle handling system.
The Go signal should be inserted into DF32 via External Go port.

For information on External Go port, please refer to section 10.

Advertising