Operator’s manual df32, 2 print current status – Watson-Marlow DF32 User Manual

Page 25

Advertising
background image

Operator’s manual
DF32

Rev.: 1.03 Date: 2007-03-12 Page 25 of 32

File:
DF32 OM 1.03 EN

9.2 Print

current

status

Function 24 prints the current parameters, and print-outs should be made after completion of the
filling series.

The printing is to be started in the following way:

<2>+<4>+<ENT>, and the following display will be shown:

F24 PRN STATUS (Y/N):_

F 1: VOLUME (ml): 50.0

Fig. 9.3

Press the <Y> key to confirm start of printing, and the printer will start.

Example of print-out:

* Flexicon DF32 V1.1 *

OPERATOR 2641

BATCH NO.

9604084438

VOLUME (ml)

50.0

FILLS PER MIN

17

NUMBER OF FILLS

100

AT FILL NO:

51

RECALIB VOL (ml):

48.7

AT FILL NO:

74

RECALIB VOL (ml):

47.9

Fig. 9.4


In addition to registering the filling series, DF32 also registers when and from which value
recalibrations were carried out.

If the print-out of the current parameters is left in the printer till the status print-out has been made,
this will give a full production documentation which might look like the one shown overleaf.

Advertising