4.1.3 Adjustment of the filling stand
Loosen the finger screw at the bottom of the filling stand.
Adjust the filling stand and the filling nozzle over the centre of the bottle – over the second bottle in the
star wheel.
The nozzle tip should only be a few millimetres away from the bottle top to avoid squirt of product.
4.2 Adjusting the capping sensor
Place a bottle with a cap in front of the sensor.
The cap must be placed detachable on the top of the bottle – not screwed.
Loosen the finger screw of the sensor and adjust until the light is just below the top of the cap.