Wavetronix SmartSensor Advance Extended Range (SS-200E) - Quick-reference Guide (User) User Manual

Page 4

Advertising
background image

WX-500-0169

© 2012 Wavetronix LLC. All rights reserved. Protected by U.S. Patent Nos. 6,556,916; 6,693,557; 7,426,450; 7,427,930; 7,573,400; 7,889,097; 7,889,098; 7,924,170; 7,991,542; 8,248,272;

Cdn. Pat. Nos. 2,461,411; 2,434,756; 2,512,689 and Euro. Pat. Nos. 1435036; 1438702; 1611458. Other U.S. and international patents pending. Wavetronix, SmartSensor, Click, Com-

mand and all associated logos are trademarks of Wavetronix LLC. All other product or brand names as they appear are trademarks or registered trademarks of their respective

holders. Product specifications are subject to change without notice. This material is provided for informational purposes only; Wavetronix assumes no liability related to its use.

10

Set up the communication with the detector rack cards

You can use SmartSensor Advance with the Click 112/114 (Z4 protocol) or the Click 104 (Z4 protocol)

contact closure modules. Communication from the sensor can be set up using the rack cards or by using

SmartSensor Manager.

To set up communication via the Click 112/114/104 modules:
1 Plug in the rack card and connect a jumper cable to the correct data push

port.

2 Hold down the push button on the faceplate until the green LED comes

on and then release it.

3 Press the button once to select autobaud on the data bus (bus 1 on the

card).

4 Press the button again to begin the autobaud process.

5 Verify that detections are registering on the Channel LEDs.

To set up communication via SmartSensor Manager
1 From the Channels-Alerts-Zones screen, click on Setup Output Communica-

tion.

2 Select Port 2 from the transmit output drop-down list. Port 2 is the data bus.

3 Select Z4 from the output format drop-down list to set up communication with

the Click 112/114. Select Simple from the output format drop-down list to set

up communication with the Click 172/174.

4 Click OK to save the communication changes.

5 Verify that detections are registering on the rack card. (Close SmartSensor

Manager if you are connected over the data bus.)

See the Click 100–400 Series User Guide for Click 104 instructions and more complete contact closure infor-

mation.

Advertising