Type tests and environmental conditions – Westermo MR-2x0 User Manual

Page 10

Advertising
background image

10

6622-2221 -29000447

Type tests and environmental conditions

Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact

± 4 kV

Enclosure air

± 8 kV

RF field AM modulated

EN 61000-4-3

Enclosure

3 V/m 80% AM (1 kHz), 80 – 1 000 MHz, 1
400 MHz – 2 000

Fast transient

EN 61000-4-4

Signal ports

± 0.5 kV

Power ports

± 1 kV

Surge

EN 61000-4-5

Telecom/Signal ports ± 0.5 kV line to earth
Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

Power ports

3V/m 80% AM (1 kHz), 0.15 – 80 MHz

Voltage dips and
interruption

EN 61000-4-11

AC power ports

10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage

Radiated emission

EN 55022

Enclosure

Class B

FCC part 15

Class B

Conducted emission

EN 55022

AC power ports

Class A

FCC part 15

AC power ports

Class B

EN 55022

DC power ports

Class B

Temperature

Operating

MR-210 / MR-260

–20 to +55º Celsius
(–25 to +70ºC restricted operation)
–4 to +131º Fahrenheit
(–13 to +158ºF restricted operation)

MR-270

0 to +55º Celsius
(0 to +70ºC restricted operation)
32 to +131º Fahrenheit
(32 to +158ºF restricted operation)

Storage &
Transport

–40 to +85º Celsius
–40 to +185º Fahrenheit

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2000 m / 70 kPa

Reliability prediction
(MTBF)

Bellcore
RQGR at 40°C

MR-210

203 000 hours

MR-260

218 000 hours

MR-270

139 000 hours

Enclosure

Pressed steel

Dimension W x H x D

MR-210 / MR-260

173 x 36 x 119 mm
6.8 x 1.4 x 4.7 inches

MR-270

210 x 41 x 150 mm
8.3 x 1.6 x 5.9 inches

Weight

MR-210 / MR-260

0.49 kg

MR-270

0.9 kg

Degree of protection

IEC529

Enclosure

IP 40

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail or flat on
level surface