Type tests and environmental conditions – Westermo RFI-xx User Manual

Page 12

Advertising
background image

12

6641-22305

Type tests and environmental conditions

Phenomena

Test

Description

Test levels

esD

eN 61000-4-2

enclosure contact

± 6 kV

enclosure air

± 8 kV

rF field AM modulated ieC 61000-4-3

enclosure

20 V/m 80% AM (1 kHz), 80 – 2700 MHz

Fast transient

eN 61000-4-4

signal ports

± 2 kV

Power ports

± 2 kV

surge

eN 61000-4-5

signal ports unbalanced

± 2 kV line to earth, ± 2 kV line to line

signal ports balanced

± 2 kV line to earth, ± 1 kV line to line

Power ports

± 2 kV line to earth, ± 1 kV line to line

rF conducted

eN 61000-4-6

signal ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power frequency
magnetic field

eN 61000-4-8

enclosure

Not susceptible to magnetic fields

Pulse magnetic field

eN 61000-4-9

enclosure

300 A/m

Voltage dips
and interruption

eN 61000-4-29

DC power ports

10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage

radiated emission

eN 55022

enclosure

Class A

FCC part 15

enclosure

Class A

Conducted emission

eN 55022

DC power ports
Telecommunication
ports Class B

Class B

Dielectric strength

eN 60950

signal port to other
isolated ports

1.5 kVrms 50 Hz 1 min

Power port to other
isolated ports

1.5 kVrms 50 Hz 1 min

Temperature

Operating

–40 to +70ºC (–40 to +158ºF) (all models*)

storage & Transport

–40 to +85ºC (–40 to +185ºF) (all models)

Maximum surface
temperature

135°C (temperature class T4)

Humidity

Operating

5 to 95% relative humidity

storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

service life

Operating

10 year

Vibration

ieC 60068-2-6

Operating

7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
(Wall-mounted or DiN-rail mounted using TH
35-15 according to eN 60175)

shock

ieC 60068-2-27

Operating

15 g, 11 ms
(Wall-mounter or DiN-rail mounted using TH
35-15 according to eN 60175)

enclosure

UL 94

Aluminium / Zink

Flammability class V-0 (all models)

* Note: rFi10-F4G-T4G and rFi18-F4G-T4G needs forced airflow to handle operating temperature above +60°C. This
can be acheived using an external fan or similar. Without forced airflow maximum operating temperature is +60°C.
refer also to "safety" section.