Interface specifications – Westermo EDW-120 User Manual

Page 22

Advertising
background image

22

6616-2211

Interface specifications

* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m

boundary to the rails and connected to this port.

The cable shield should be properly connected (360°) to an earthing point within 1 m from this port. This

earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet,

or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing system

of an installation and may be directly connected to the protective earth.

Power LV

Rated voltage

12 to 48 VDC

Operating voltage

10 to 60 VDC

Rated current

200 mA @ 12 VDC
100 mA @ 24 VDC
50 mA @ 48 VDC

Rated frequency

DC

Maximum inrush
current @ 10 ms

0.13 A

2

s @ 48 VDC

Power up current

< 0.3 A. Sensitive power supplies need current limit >= 0.3A

Polarity

Reverse polarity protected

Redundant power input

Yes

Isolation to

All other 2 k V

rms

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Shielded cable

Not required

RS-232

Electrical specification

EIA RS-232

Data rate

300 bit/s – 115.2 kbit/s

Data format

7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits.

Protocol

Transparent, optimised by packing algorithm

Retiming

Not applicable

Circuit type

SELV

Transmission range

15 m

Isolation to

Power 2 kV

rms

Ethernet 1; 1.5 kV

rms

Connection

9-pin D-sub male (DTE)

Shielded cable

Not required, except when installed in Railway applications as signalling
and telecommunications apparatus and located close to rails*

Conductive housing

Isolated to all other circuits

Number of ports

2 (port A and B)