6640-2205

Location of interface ports and LED’s

Ethernet connection TX (6 ports)

Contact Signale  Direction  Description

No.1

TD+

In/Out

Transmitted/Received data

No. 2

TD–

In/Out

Transmitted/Received data

No. 3

RD+

In/Out

Transmitted/Received data

No. 4

Not Connected

No. 5

Not Connected

No. 6

RD–

In/Out

Transmitted/Received data

No. 7

Not Connected

No. 8

Not Connected

Shield

HF-connected

NOTE! Railway installation close to the rails.
For a cable located inside 3 m boundary and connected to this 
port, the use of shielded cable is recommended, this is to mini-
mise the risk of interference. The cable shield should be prop-
erly connected (360°) to an earthing point within 1 m from 
this port. This earthing point should have a low impedance con-
nection to the conductive enclosure of the apparatus cabinet, 
or similar, where the unit is built-in. This conductive enclosure 
should be connected to the earthing system of an installation 
and may be directly connected to the protective earth.

LED Indicators (for details see page 13)

Power, screw terminal (for details see below)

FX(Fibre)  

(for details see page 11)

Fault contact (for details see below)

4-position

Description

No. 1

+DC1

No. 2

+DC2

No. 3

Common

No. 4

Common

The Lynx series supports redundant 
power connection. The positive inputs 
are +DC1 and +DC2, the negative input 
for both supplies is  –COM. Connect 
the primary voltage (e.g. +24 VDC) to 
the +DC1 pin and ground to one of the 
–COM pins on the power input on the 
Lynx switch by using the enclosed power. 

4-position

Description

No. 1

Alarm relay (status) +

No. 2

Alarm relay (status) –

No. 3

No. 4

W

estermo

Teleindustri www

.westermo.com

Input voltage: 19-60VDC max 7W Date of mfg (Y/M/D): 2006-10-17

MAC: 00:07:7c:80:24:ae Serial no: lx4232

Lynx 3640-4030

L1407F1- MM-SX-LC550

+DC1

+DC2

-COM

-COM

Power connection  
screw terminal

Fault contact

W

estermo

Laser Class 1 Product

Digital in -

Digital in +

Status -

Status +

W

estermo T

eleindustri

AB

SE-640 40 Stora Sundby Sweden

Sweden www

.westermo.com

lx003967

Country of origin: