Type tests and environmental conditions – Westermo MRD-315 User Manual

Page 10

Advertising
background image

10

6623-2250

Type tests and environmental conditions

Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact

± 6 kV (crit A)*

Enclosure air

± 8 kV (crit A)*

RF field AM modulated

IEC 61000-4-3

Enclosure

10 V/m (crit A)*

(80 – 2700 MHz)

Fast transient

EN 61000-4-4

Signal ports

± 1 kV (crit A)*

Power ports

± 2 kV (crit A)*

Surge

EN 61000-4-5

Ethernet ports

± 1 kV (direct) (crit B)*

Power ports

± 0.5 kV (line to earth) (crit B)*

± 0.5 kV (line to line) (crit B)*

RF conducted

EN 61000-4-6

All ports

10 V/m, (crit A) *

(0.15 – 80 MHz)

Radiated emission

EN 55022

Enclosure

Class B

Conducted emission

EN 55022

DC power ports

Class B

Ethernet ports

Class B

Temperature

Operating

–40 to +70ºC

Storage & Transport

–40 to +85ºC

Humidity

Operating

0 to 90% relative humidity non

condensing.

Storage & Transport

0 to 90% relative humidity non

condensing.

Altitude

Operating

2000 m/70 kPa

MTBF

MIL-217-F

MRD-315

825 759 hours

MRD-355

689 933 hours

MRD-455

689 933 hours

Service life

Operating

10 year

Dimension W x H x D

53 x 103 x 134 mm

Weight

0.40 kg

Degree of protection

IEC 529

Enclosure

IP 40

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail

*crit A = no effect, crit B = restart without user intervention