3-28

6. V-Link

- Type

- Address

Specify the memory address to be accessed.

- Expansion code

Set the slot number of the SPU memory of the MITSUBISHI PLC or the CPU
number of the YOKOGAWA PLC.

Example:

MITSUBISHI Slot No. 0:

00H

MITSUBISHI Slot No. 1:

01H

YOKOGAWA CPU No. 1: 00H
YOKOGAWA CPU No. 2: 01H

- Port number

1 : 1, Multi-link............................................ Not used
Multi-drop................................................... PLC port number
Temperature controller............................... Temperature controller port number

- File No.

Specify the file number set in the [Memory Card Setting] dialog of the V-SFT editor.

- Record No.

Specify the record number set in the [Memory Card Setting] dialog of the V-SFT
editor.

- System reserved

Enter “0” (= 30 in the ASCII code) for the number of bytes. The number of bytes for
“system reserved” varies depending on the model.

Example:

Type

Code

(Hexadecimal)

ASCII

V7 internal
memory

$u (user memory)

00H

3030

$s (system memory)

01H

3031

$L (non-volatile word memory)

02H

3032

$LD (non-volatile double-word memory)

03H

3033

PLC memory

Depends on the PLC to be used. Set the type number indicated for
“Available Memory” of respective PLCs on the Hardware Specifications.

Temperature
control/PLC2
memory

Depends on the PLC to be connected to the temperature controller and
PLC2 function. Set the type number indicated for “Available Memory” of
respective temperature controllers on the Temperature Control Network
Manual. Set the type number indicated for “Available Memory” of respective
PLCs on the Hardware Specifications when using the PLC2Way function.

Model

No. of Bytes

Code (Hexadecimal)

ASCII

V7 internal memory

10

0000000000H

30303030303030303030

* If no expansion code or port number

is required, enter “00” (= 3030 in the
ASCII code).