Hakko MONITOUCH V7 series User Manual

Page 342

Advertising
background image

5

29. Automationdirect PLC

5-135

Co
nne

c

tio

n

to P

L

Cs

RS-422

Wiring Diagram 5

Wiring Diagram 6

V7 (CN1)

FG

+SD

−

SD

+RD

−

RD

1

12

13

24

25

RXD+

RXD

−

PLC

CTS1+

TXD1+

TXD1

−

RTS1+

RTS1

−

CTS1+

9

10

11

14

16

18

19

23

SG

7

SG

7

* Use shielded twist-pair cables.

D-sub 25-pin (male)

D-sub 25-pin (male)

V7 (CN1)

FG

+SD

−

SD

+RD

−

RD

1

12

13

24

25

TXD3+

TXD3

−

PLC

RXD3+

RXD3

−

12

13

24

25

SG

7

SG

7

* Use shielded twist-pair cables.

D-sub 25-pin (male)

D-sub 25-pin (male)

In case SU-6M, it is possible
to use terminal blocks,

Advertising