Hakko MONITOUCH V7 series User Manual

Page 197

Advertising
background image

4-46

1. Ethernet

• System memory: $s518

No.

Contents

Solution

0

Normal

200

Failed in send request

Check cable connection and network table setting of
the target station.

201

Send error

Check that the setting on the target station is
consistent with the network table setting.

202

Internal port error

The communication unit is in the older version or is
faulty.

204

TCP connection over

The number of connections reaches the maximum,
and no more connection is possible. Check the
communication lines.

205

TCP connection error

Connection cannot be established. Check the
communication lines, or turn the power off and on.

206

TCP connection end error

TCP communication disconnection has failed. Check
that the communication partner with the V7 series is
present on the line.

207

TCP send error

TCP sending has failed. Check the communication
lines.

350

Send buffer full

The line is busy. Consult the network administrator of
your company. The communication unit is in the older
version or is faulty.

351

IC receive buffer overflow

352

Driver receive buffer overflow

801

Receive processing error, link down error

Check the HUB or the link confirmation LED on the
communication unit. If the LED is not on, check cable
connection and the port setting on the network table.

802

Transceiver error

Check the transceiver and cable connection.

900

No IP address at local port

Check that the IP address of the local port is set on
the network table. Check if the same IP address is set
on the network.

901

Duplicated IP address error

902

Send socket ID error (error that may
occur when V7i LAN port is used)

Turn the power off and back it on. If the problem
persists, contact your local distributor.

1000

Ethernet I/F unit not mounted

Check whether the Ethernet I/F unit is mounted
correctly, and then turn the power off and on. If the
problem persists, contact your local distributor.

1001

Ethernet I/F unit not ready

1002

Ethernet I/F unit DPRAM error

1003

No response from Ethernet I/F unit

1004

Ethernet receive buffer over

1005

Ethernet send registration error

1006

I/F unit unregistered interrupt

1100 - 1115

Initialization error (communication unit)

1120

Dual port access error

1200

Undefined register

1201

Send/receive buffer area over

1202

MAC address error

1203

Port error

Check whether the Ethernet I/F unit is mounted
correctly, and then turn the power off and on. If the
problem persists, contact your local distributor.

1301

Watch dog overflow

1302

JAVA error LANC error

Advertising