Press and hold the orange tab as you insert the wire through the pin slot, then release the orange

tab to secure the wire.

To connect digital input / output devices (DI/DO), map the pins to one of the pin combinations

below:

Device

Pin

Mapping Instructions

Digital Output (DO)

12V

Connect the wires of the output device to

12V

and

DO

.

DO

Digital Input (DI)

GND

Connect the wires of the input device to

GND

and

DI

.

DI

The table below shows the DI/DO connection specifications:

Device

DI

Connection design

TTL - compatible logic levels

Voltage

To trigger (low)

Logic level 0: 0V ~ 0.4V

Normal (high)

Logic level 1: 3.1V ~ 30V

Current

10mA ~ 100mA

DO

Connection design

Transistor (Open Collector)

Voltage & Current

< 24V DC, < 50mA

For DI/DO Use