8maintenance / diagnostics / repairs, Press, Speed – ARAG BRAVO DSB User Manual

Page 12: Fill, Flow, Feedback on, 9technical data

Advertising
background image

8

MAintenAnce / diAgnostics / rePAirs

- Only use a soft damp cloth for cleaning.
- DO NOT use detergents or aggressive substances.

ProBLeM

cAuse

soLution

The ON light does not switch on

Wrong connections

Check cabling connections

Computer switched off

Push the start up button on the
computer / monitor

The LED indicating pressure
(

PRESS

) flashes

Wrong connection

Check transducer connection

The transducer does not work

Replace the transducer

The LED indicating pressure
(

PRESS

) does not switch on

The transducer wire is not
connected

Check cabling connection

The transducer does not work

Replace the transducer

The computer / monitor does not
visualise the signal of
• speed (

SPEED

)

• filling (

FILL

)

• pressure (

PRESS

)

• rpm (

RPM

)

coming from the simulator

Wrong connections

Check cabling connections

Wrong selection of the function

Check the position of the switch

The regulation values are at
minimum

Turn the control knob clockwise

Configuration of computer /
monitor

Check that the computer / monitor has
the function requested and/or that it is
correctly configured

The computer / monitor does not
visualise the signal of :
• flow (

FLOW

)

coming from the simulator

Wrong connections

Check cabling connections

Wrong selection of the function

Check the position of the switch

The regulation values are at
minimum

Turn the control knob clockwise

Configuration of computer /
monitor

Check that the computer / monitor has
the function requested and/or that it is
correctly configured

The

FEEDBACK ON

switch is in the ON position

Turn the

FEEDBACK ON

switch to OFF (lower the lever)

The computer is not able to carry
out automatic regulation

Wrong connections

Check cabling connections

Configuration of computer /
monitor

Check that the computer / monitor
is set to automatic mode

The

FEEDBACK ON

switch is in the OFF position

Turn the

FEEDBACK ON

switch to ON (lift the lever)

Wrong position of the switches

SPEED

FLOW

Move the switches

SPEED

FLOW

down

Make sure no regulation alarm is

active on the display of

Bravo 180 - 300S - 400

Increase or decrease speed
(

SPEED

) until the light goes off

Tab. 6

9

technicAL dAtA

• Size

130 x 370 x 450 mm

3

• Weight

4750 gr

• Power supply

9 ÷ 15 Vdc

• Current absorbed

0,2 A to 12 Vdc

• Low battery signal

10,5 Vdc

• Working temperature

0° ÷ 50°C

(+32 ÷ 122 F)

• Storage temperature

-20° ÷ 70°C
(-4 ÷ 158 F)

Tab. 7

12

Advertising
This manual is related to the following products: